Generator Knowledge

  • The reason for the generator to lose magnetism

    The reason for the generator to lose magnetism

    During the normal operation of the generator, the excitation suddenly disappears in whole or in part, which is called the generator loss of magnetism. The causes of generator excitation loss can generally be summarized as open excitation circuit or short circuit, including exciter, excitation cha...
    Read more
  • Main performance index of diesel engine and gasoline engine of generator set

    Main performance index of diesel engine and gasoline engine of generator set

    The main performance indexes of diesel engine and gasoline engine include power, thermal efficiency, mechanical efficiency, fuel consumption rate, torque and so on. 1. Power Mechanical work performed per unit time of an internal combustion engine, in kW. Power has indicated power and effective p...
    Read more
  • Daily check diesel generator set matters

    Daily check diesel generator set matters

    First, check before starting. 1. Check whether the oil level of the oil scale is between L and H to see if there are any abnormal signs of oil quality. 2. Check whether the cooling water in the water tank is enough, whether the water valve is opened, and whether the cooling water is abnormal. 3....
    Read more
  • Diesel engine operation precautions

    Diesel engine operation precautions

    Before starting the diesel engine, pay attention to check the oil, cooling water, fuel level and pipeline connection, and turn the crankshaft several turns to confirm that the rotation is barrier-free. When the diesel engine starts, if it does not start within 15 seconds, it should be started aga...
    Read more
  • How to clean dry air filter

    How to clean dry air filter

    When the maintenance indicator on the filter shows a red signal or the resistance of the filter affects the performance of the diesel engine, the filter must be cleaned or the filter element must be replaced. 1) Remove the main filter element of the filter. 2) Turn the open end face down and car...
    Read more
  • Effective methods and techniques for fault diagnosis and maintenance of diesel generator sets

    Effective methods and techniques for fault diagnosis and maintenance of diesel generator sets

    Diesel generator sets play an important role in modern society. However, due to the working environment, use conditions and other reasons, these devices may have various failures. This article will introduce some effective methods and tips to help you better diagnose and repair diesel generator f...
    Read more
  • What are the precautions when using diesel generators in winter

    What are the precautions when using diesel generators in winter

    With the development of society, human beings rely more and more on electricity. Diesel engine, as a common standby power supply equipment, has attracted more and more attention for its advantages of convenience, fast and easy operation, and has become a standby power product. For factory enterpr...
    Read more
  • 800KW plateau diesel generator set

    800KW plateau diesel generator set

    About the 800KW plateau diesel generator set, we will introduce its basic mechanism and working principle, and then discuss its applicability in the plateau environment, and then discuss its application in emergency backup power supply and conventional power generation, and summarize its advantag...
    Read more
  • Beidou in International Consumer Rights Day

    Beidou in International Consumer Rights Day

    The development of an enterprise is built upon the pillars of quality and integrity. On this significant occasion, International Consumer Rights Day on March 15th, we make a solemn commitment that our diesel generator sets will never be counterfeited or falsely labeled.
    Read more
  • 7 Reasons Cause Insufficient Output Power of Diesel Generator Sets

    7 Reasons Cause Insufficient Output Power of Diesel Generator Sets

    1.Diesel filter clogged causing oil supply obstruction. 2.The fuel delivery pipeline is leaking and air is mixed into the fuel pipe. 3.The engine air filter clogged, causing poor air intake. 4.Fuel temperature is too high. 5.Engine exhaust back pressure is too high, causing poor engine exhaust. 6...
    Read more
  • 600KW Container Type Diesel Generator Acceptance

    600KW Container Type Diesel Generator Acceptance

    After the lively Spring Festival, Yangzhou experienced heavy snowfall with goose feathers, and the weather was very cold. We completed the acceptance work of a 600KW containerized diesel generator set with the customer in a cold outdoor environment. It is a customized 600KW diesel generator, powe...
    Read more
  • Why emergency power supply vehicle is a necessary equipment for the national grid?

    Why emergency power supply vehicle is a necessary equipment for the national grid?

    Today we got a emergency power supply vehicle ready to deliver to State Grid Corporation of China Zhejiang Jian branch.  In this case, we used Dongfeng vehicles quipped with Cummins generator. Let’s check the advantages of power supply vehicle.    Advantages of emergency power supply vehicl...
    Read more