  • How to check the diesel generator set indicators

    How to check the diesel generator set indicators

    The use of diesel generator sets will involve the usual maintenance and maintenance, the main responsibility of the maintenance contractor is to check the system, study the technical data provided by the manufacturer, maintain records, and take safety measures according to the manufacturer’...
    Read more
  • Method for adjusting injection advance Angle of diesel generator

    Method for adjusting injection advance Angle of diesel generator

    In order to make the diesel engine to get good combustion and normal work, and to obtain economic fuel consumption rate, every time the diesel engine work 500h or each disassembly, it must be checked and adjusted the injection advance Angle. Injection advance Angle adjustment method: 1) The firs...
    Read more
  • Does the valve guide affect the fuel consumption of the generator set

    Does the valve guide affect the fuel consumption of the generator set

    The wear degree of the valve guide will affect the oil consumption of the diesel generator set. What measures can be taken to make the machine more fuel-efficient? 1) Maintain the oil supply Angle: the oil supply Angle is offset, which will cause the oil supply time to be too late, and the oil c...
    Read more
  • What causes the fuel injector stuck in the generator set

    What causes the fuel injector stuck in the generator set

    The fuel injector is an important part of the generator set, but the fuel injector sometimes occurs stuck, what is the cause of this? Take a look at the generator Beidou Power brief introduction. The fuel used in the diesel generator set is not clean, contains too much impurities, impurities wil...
    Read more
  • What is the role of the lubricating oil of the generator set

    What is the role of the lubricating oil of the generator set

    Oil, that is, engine oil, can lubricate the engine and reduce wear, assist cooling and cooling, seal and prevent leakage, rust and corrosion, shock and buffer. We know that when the generator set is running, there will be a lot of mutual friction movement of the metal surface, the movement speed...
    Read more
  • How to identify whether the diesel generator lubricating oil has deteriorated

    How to identify whether the diesel generator lubricating oil has deteriorated

    How to identify whether the diesel generator lubricating oil has deteriorated? After the use of lubricating oil for a period of time, due to the pollution of mechanical impurities and dust from the outside world, the exhaust gas produced by fuel combustion, water, particles, metal chips worn dow...
    Read more
  • Diesel generator set Diesel engine working principle

    Diesel generator set Diesel engine working principle

    The basic working principle of diesel engine is that diesel fuel is injected into the cylinder and burns rapidly, forming high temperature and high pressure gas, pushing the piston to move down, and driving the crankshaft through the connecting rod, so that the heat energy is converted into mecha...
    Read more
  • Advantages of Yuchai diesel generator set

    Advantages of Yuchai diesel generator set

    Yuchai diesel generator set constant pressure control system, high sea treatment are highly configured according to international standards. Yuchai standard unit control panel is the most basic configuration to meet the normal operation and use of the unit, with the advantages of simple operation...
    Read more
  • The method of judging the fault of diesel generator set

    The method of judging the fault of diesel generator set

    Diesel generator set in the use of the process sometimes there will be a variety of failures, a variety of phenomena, the causes of failure are also diverse, a fault may occur a variety of abnormal phenomena. No matter where the generator set failure will cause the diesel generator set can not wo...
    Read more
  • Diesel generator power reduction reasons

    Diesel generator power reduction reasons

    The reasons for the power decline of diesel generator sets are as follows: 1. The air filter is too dirty, and the suction air is not enough;   2. The fuel filter device is too dirty and the injection amount is not enough;   3. The ignition time is not correct;   4. The degree of ...
    Read more
  • Things to pay attention to when using diesel generators in field construction

    Things to pay attention to when using diesel generators in field construction

    In field construction, the daily maintenance and correct operation mode of diesel generator set are important measures to extend the service life of the unit and reduce the failure. The selection of field construction generator sets should pay attention to the selection of brand and configuratio...
    Read more
  • The reason for the generator to lose magnetism

    The reason for the generator to lose magnetism

    During the normal operation of the generator, the excitation suddenly disappears in whole or in part, which is called the generator loss of magnetism. The causes of generator excitation loss can generally be summarized as open excitation circuit or short circuit, including exciter, excitation cha...