Which diesel generator checks should be done by electricians?
As we all know, diesel generators must pass strict inspection before they are put into operation. Strictly speaking, some tests are not for everyone and need to be performed by professionals. For example, some inspections must be carried out by professional electricians. Which diesel generator ch...Read more -
What quality standards should communication diesel generators meet?
After years of development, diesel generators have formed a quality standard system with unique characteristics, and the quality standard is different for different uses. Diesel generators have high requirements and strict quality standards. What kind of quality standard does the communication di...Read more -
Cummins Diesel Generator oil level abnormal analysis?
When the Cummins diesel generator transformer is running, the normal flow must be maintained. The officer on duty must check the revised instructions immediately. When the oil level is too high (summer, etc.), it must be immediately supplemented when the oil level is too low (winter, etc.), and t...Read more -
How to prevent bubbling of fuel tank of diesel generator set?
How to prevent bubbling in the oil tank of the diesel generator set is because the high-pressure gas in the oil cylinder intrudes into the cooling waterway. The causes and methods of gas channeling are as follows. 1. The head nut is not fastened according to the specified torque. If the torque is...Read more -
The 10 requirements and characteristics of diesel generator oil pump?
Diesel generator oil pump is an important part. Generally speaking, in order to ensure the use of the organs of the diesel generator set, great attention must be paid to the use and installation of the oil pump. 1. Before installing the oil pump, make sure that the model and specification are cor...Read more -
Is there usually electricity on the neutral line? Zero line? When is the electricity on?
A lot of people talk about whether the neutral line has electricity or not in the general case. Anyway, there are two points of view. One has electricity, one is dead. As for whether there is biography, it actually confuses people’s concept of electrification, considering only their own vie...Read more -
Diesel Engine Frequent Oil Leakage Fault Analysis?
First, first, how to check the diesel generator: first check whether the type, quantity and quality of the oil meet the requirements. Second, diesel engine components of the combined surface is smooth, size processing is in line with the requirements. Dumping materials and die casting without san...Read more -
Main fault precursor of diesel engine?
Let’s look at the main failure precursors of diesel generators and the precursors of watt combustion. Diesel engine starts, speed drops sharply, load increases, the engine takes black smoke, oil pressure drops, crankcase issued dry friction sound “goo”, is the precursor of burni...Read more -
Diesel generator Running in parallel Precautions?
To increase production efficiency, many companies have two generators. However, the parallel operation of generator sets is more than just mixing two generator sets. Diesel generator sets must also meet appropriate normal operating conditions. (1) The effective voltage value of the generator set ...Read more -
Common operating Faults of diesel generators?
What is the wrong way to operate a diesel generator? Operation Error 1: The diesel engine operates in a shortage of oil. Due to the shortage of oil, the fuel supply on each friction surface is insufficient, which may lead to abnormal wear and burns. Therefore, it is necessary to ensure sufficient...Read more -
What are the safe operation steps of diesel generator sets?
Today a brief introduction to the mobile power company. Safe operation rules for diesel generators: 1. After receiving the operation readiness signal, carefully check whether the diesel engine lubrication is on the specified oil, check the amount of oil and water, remove the relevant things near ...Read more -
What causes excessive oil consumption in diesel generators?
The excessive consumption of lubricating oil for diesel generators is also caused by various reasons. Only by finding out the specific cause can we troubleshoot the problem according to the cause. Once the problem is solved, two problems are solved, one is the problem of unit failure, the other i...Read more