Company News

  • Diesel generator fan belt adjustment

    Diesel generator fan belt adjustment

    Diesel fan belt is too tight, will make direct (AC) flow generator bearing, water pump bearing, fan bearing wear intensifies; The loose belt will cause insufficient fan air volume, affecting the cooling effect of cooling water, while the output voltage of the generator decreases, the flow rate of...
    Read more
  • Methods of repairing diesel engine gear

    Methods of repairing diesel engine gear

    First, reversing method: For single-side wear of the gear face, if the structure allows, the gear can be changed or turned 180 degrees, using its unworn side, but it is better to use in pairs, or replace the gear with a new product to ensure the normal mesh of the gear. Second, insert ring metho...
    Read more
  • Wrong operation and maintenance methods can also cause diesel engine failures

    Wrong operation and maintenance methods can also cause diesel engine failures

    The failure of diesel engine in the use of construction machinery occurs from time to time, so I visited and investigated some construction machinery repair plants and construction units with a large number of construction machinery. The investigation found that the fault caused by the diesel eng...
    Read more
  • The measures we take when the engine radiator breaks into water

    The measures we take when the engine radiator breaks into water

    The hose of the engine radiator will be aging and easy to break for a long time. If the radiator enters the water and the hose breaks during driving, the high temperature water spattered out will form a large group of water vapor from under the engine cover. When this phenomenon occurs, you shoul...
    Read more
  • Reasons for cylinder liner cavitation of diesel generator set

    Reasons for cylinder liner cavitation of diesel generator set

    The characteristics of cylinder liner cavitation damage are in the form of locally gathered deep holes. In most cases, the damaged surface is clean, free of deposition of corrosion products, and appears on one side of the liner pressure surface. With the development of diesel engine to the direct...
    Read more
  • Maintenance method for flatness of cylinder block of diesel generator set

    Maintenance method for flatness of cylinder block of diesel generator set

    In use, the cylinder block of the generator set is susceptible to overload operation or the failure of the cooling system and lubrication system, resulting in deformation, warping or damage. The flatness of the cylinder block can be checked in the following two ways. Check with straightening gau...
    Read more
  • Battery maintenance tips for generator maintenance

    Battery maintenance tips for generator maintenance

    At present, the starting battery of the generator set used by many customers is still the kind of battery that adds the battery water. Special attention should be paid to the use of this battery: When the battery of the diesel generator set is not used for a long time, it must be properly charge...
    Read more
  • Generator maintenance site

    Generator maintenance site

    The diesel generator set is generally bought as a backup, so it has been in a state of standby waiting for use, but it is generally rarely used, and the generator is usually in a state of standby lack of detection, maintenance, etc., but the generator is an essential backup power supply, if it is...
    Read more
  • What is a diesel generator jet

    What is a diesel generator jet

    Diesel generator injector nozzle is actually a simple solenoid valve, when the solenoid coil is energized, the suction force is generated, the needle valve is sucked up, the spray hole is opened, and the fuel is sprayed at high speed through the annular gap between the shaft needle and the spray ...
    Read more
  • Diesel generator power calibration

    Diesel generator power calibration

    Speaking with quality, sincere cooperation is the concept of our company. With excellent product quality and service quality occupy a broad market. There are many diesel generator sets, in this Beidou power generation equipment factory to take you to understand the power calibration of diesel gen...
    Read more
  • Diesel generator set lightning protection knowledge

    Diesel generator set lightning protection knowledge

    The fuel used by the domestic diesel generator set is mainly light diesel, its lightning is generally not less than 65 ° C, higher than the ambient atmospheric temperature, diesel is a flammable liquid that may cause fire danger, and the power station with diesel should belong to the H-1 fire dan...
    Read more
  • What is a generator excitation system

    What is a generator excitation system

    What is a generator excitation system? Generator excitation system The power supply that supplies the synchronous generator excitation current and its auxiliary equipment are collectively referred to as the excitation system. It is generally composed of two main parts: excitation power unit and e...
    Read more
123456 Next > >> Page 1 / 19