The speed of the diesel generator is unstable after starting?
Cause of failure: Air enters the oil supply pipeline; improper adjustment of the gain or stability of the speed control plate; excessive opening of the speed control rod.
Troubleshooting: Check the oil supply pipeline and deal with the parts where there is air leakage to prevent air from entering the oil supply pipeline. Re-set the gain and stability adjustment potentiometers on the speed control board; according to the value of overspeed or low speed, properly reduce or increase the opening of the speed control lever before starting the machine, and then start the machine, and then adjust the speed according to the speed of the engine. adjustment lever opening.
Post time: Sep-02-2022