Storage of diesel generator sets for site construction

It is convenient for the scientific calculation of the warranty period of the diesel generator set in the field construction, to meet the user’s desire to put into use as soon as possible, and the normal maintenance of the diesel generator set. It is recommended to install and debug the diesel generator set immediately after it arrives at the site, and arrange full-time personnel to be responsible for the operation and daily maintenance of the diesel generator set.
If the diesel generator set needs to be stored for a period of time due to some special reasons, a reasonable and feasible storage scheme should be formulated according to the length of time. The storage of diesel generator set will have a decisive adverse effect on diesel engine and main alternator, so the correct storage method is very necessary.
The storage of diesel generator sets during site construction should be carried out according to the steps, including the cleaning of diesel generator sets, the drying and ventilation of diesel generator sets, the replacement of new lubricating oil of appropriate quality, the coolant in the water tank and the anti-rust treatment of diesel generator sets.
The storage location of the diesel generator set should be able to ensure that it is not hit by trees and objects, so as to avoid damage. In addition, users are advised to set up independent warehouses and not place inflammable and explosive materials around diesel generators. It is necessary to have some fire protection measures, such as placing a *BC class fire extinguisher.
In order to prevent moisture from entering the main alternator coil, which will greatly reduce moisture condensation, reduce the insulation performance of the generator, and even affect the availability of the diesel generator set, attention should be paid to keep the environment around the generator dry, or take appropriate heating devices and other special measures to make the coil always maintain the necessary dry.
Storage of diesel generator sets should be protected from overheating, undercooling or rain and sunlight. The starting battery of diesel generator set in site construction is lead-acid high-energy battery. Users are advised not to add electrolytes before commissioning diesel generator sets. If added, care should be taken to charge every 5 to 8 weeks to avoid battery damage or reduced service life. When storing batteries, avoid direct exposure to sunlight or rain.
After storage for a period of time, check whether the diesel generator set is damaged, whether the electrical components of the diesel generator set are oxidized, whether all the connecting parts are loose, and whether the coil of the main generator is kept dry before installation and use. Appropriate measures should be taken if necessary. The preceding information also applies to the installation of the diesel generator set in the equipment room.