Will the diesel generator set filter be changed too quickly?
Customers who often use diesel generator sets will find a problem – the oil filter of diesel engine is shorter than that of gasoline engine, and the replacement frequency is higher, mainly because of the higher quality requirements of high-precision components of diesel supply system. The c...Read more -
Introduction to the method of judging the fault of silent diesel generator?
The silent diesel generator should flexibly use different methods of troubleshooting for different fault phenomena, and find the solution to the problem from the working principle and structure of the silent diesel generator. Considering that various fault phenomena of silent diesel generators ar...Read more -
The harm of not timely maintenance during the operation of diesel generators?
1. The excitation circuit is grounded. There are two types of grounding of the excitation circuit: one-point grounding and two-point grounding. Generally speaking, when the excitation circuit is grounded at one point, there is no serious harm to the diesel generator. However, if the maintenance i...Read more -
Check and repair Volvo genset timing gear operation?
The timing gear on the camshaft of the Volvo genset will wear for too long, which will cause the backlash to fire, so it will produce noise during operation. When their fitting clearance is greater than 0.20mm for bakelite (more than 0.15mm for steel), the gears need to be replaced. The minimum b...Read more -
What is the diagnosis and solution for the low water temperature of the Cummins generator set and the “overturning water” of the water tank?
Do not add ordinary tap water or deep well water to the water tank of the Cummins generator set, because the mineral content in these waters is relatively high, and it is more likely to produce scale once a long time, which can easily lead to clogging of the water tank. And the water tank of the ...Read more -
When does diesel generator set need electrical maintenance?
The main purpose of conducting electrical maintenance work is to keep the diesel generator set in good operating condition. Therefore, in the process of electrical maintenance, we must not only follow the standard maintenance procedures, but also pay attention to the safety of maintenance operati...Read more -
How to improve the performance of diesel generator sets in complex environments?
Since the environment of each region is different, in order to ensure the normal operation of the diesel generator set, we must fully consider the impact of various complex environments on the generator set, and then take corresponding countermeasures to create a good operating environment for th...Read more -
What important role do diesel generators play in ensuring power for communication equipment?
With the rapid development of my country’s communication industry, the continuous modernization of communication means, the continuous updating of various communication equipment, the improvement of technical level, the continuous expansion of the installed capacity of each telecommunicatio...Read more -
What is the reason for the high fuel consumption of diesel generator sets?
Where did the diesel generator set oil go? Part of it ran into the combustion chamber due to “channeling oil”, was burned or formed carbon deposits, and the other part leaked from the place where the seal was not tight. The oil generally enters the combustion chamber through the gap b...Read more -
Why do diesel generators have altitude restrictions?
As to why there is an altitude limit for using a diesel generator, know that with a naturally aspirated diesel engine, the combustion conditions deteriorate due to insufficient intake air, and the diesel engine cannot reach the normal rated power. Diesel generators are marked with an altitude ran...Read more -
The reason and treatment of Volvo generator oil pan water ingress failure?
First check whether the sealing gasket of the Volvo generator oil cooler is aging or damaged. If so, replace the sealing gasket, and check whether the oil cooling core is damaged by water pressure test. If so, repair or replace the new oil cooler core. For the air cooler, the water pressure test ...Read more -
What are the basic principles of Cummins generator set parts inspection?
It should be known that the inspection work during the maintenance of Cummins generator sets contains a wide range of contents. To a large extent, it is the main basis for formulating maintenance process measures. It determines the abandonment of parts, determines the quality of assembly, and aff...Read more