News

  • What kind of fault does the blue exhaust gas of the generator set represent?

    What kind of fault does the blue exhaust gas of the generator set represent?

    Blue smoke The lubricating oil enters the cylinder and evaporates into blue oil and gas. Blue smoke is emitted with the exhaust gas. The main reasons are: 1, the air filter is blocked, the air intake is not smooth or the oil surface in the oil basin is too high (oil bath type air filter). 2. Lubr...
    Read more
  • What kind of fault does the black exhaust gas of the generator unit represent?

    What kind of fault does the black exhaust gas of the generator unit represent?

    Diesel oil is a complex hydrocarbon. The unburned diesel oil injected into the combustion chamber is decomposed at high temperature and forms black carbon. When vented, it is discharged with the exhaust gas to form black smoke. Black smoke is an incomplete combustion of fuel in the combustion cha...
    Read more
  • Method and Key points of Low temperature starting of Diesel Generator Set?

    Method and Key points of Low temperature starting of Diesel Generator Set?

    Cold starting refers to starting at an ambient temperature lower than O ° C. When starting, the user should adopt the corresponding low temperature auxiliary starting measures according to the actual ambient temperature. Measures generally taken are as follows: ① Preheat the engine oil and coolan...
    Read more
  • How to start diesel generator set?

    How to start diesel generator set?

    1. Automatic start of unit protection: Set the key switch to the automatic state, and judge the start by detecting the status of circuit breakers 441 and 442. When the circuit breakers 441 and 442 are detected, the generator set controller will automatically start the diesel engine set as if the ...
    Read more
  • The Cause and Treatment of diesel generator output power shortage?

    The Cause and Treatment of diesel generator output power shortage?

    Diesel generator output is lacking Fault cause: blockage of fuel filter constitutes poor oil supply; Fuel oil pipeline leakage, air into the intake pipe; The air filter of the initiator is blocked and the intake is not smooth. Fuel temperature is too high; The exhaust pressure of the initiator is...
    Read more
  • The engine can not reach the rated speed of the cause and solution?

    The engine can not reach the rated speed of the cause and solution?

    1. The engine load is too large relative to the rated power Solution: Reduce the load 2. The tachometer is faulty Solution: Check with a handheld tachometer 3. Throttle control lever is improperly adjusted Solution: Check the throttle stroke 4. The oil suction circuit is blocked Solution: Clean t...
    Read more
  • Diesel generator set long-term placement precautions?

    Diesel generator set long-term placement precautions?

    Diesel generator set as a large and medium-sized power generation equipment, occasionally used, so some enterprises will have a long time without the phenomenon, then for the long-term good storage of the unit, should pay attention to what matters, for you a few tips: 1. Exhaust diesel oil and lu...
    Read more
  • What are the inspection methods for diesel engine failure?

    What are the inspection methods for diesel engine failure?

    What are the methods to check the fault of diesel generator? 1. Partition method. The partition method is to stop the single cylinder of the diesel engine or stop the injection of several or even all cylinders one by one, and observe the work changes before and after the diesel engine and stop th...
    Read more
  • What points should be paid attention to when installing diesel generator set?

    What points should be paid attention to when installing diesel generator set?

    What aspects should be paid attention to in the installation process of diesel generator set? 1. Generator installation program The installation procedure of generator equipment is mainly: stator position → stator and rotor water pressure test → generator through the rotor → hydrogen cooler insta...
    Read more
  • How to determine the replacement time of diesel generator oil and three filters?

    How to determine the replacement time of diesel generator oil and three filters?

    How to determine the replacement of diesel generator set oil and machine filter, wood filter and air filter? Teach you three ways to get it done: 1, with two 0.5cm diameter, 20 cm long glass test tube, respectively loaded with 19 cm of new oil and used oil, sealed two tubes inverted at the same t...
    Read more
  • Diesel generator common problem solution?

    Diesel generator common problem solution?

    A series of problems will inevitably occur in the daily use of diesel generator set, so how to solve them effectively? 1, the generator (electric ball) loss of magnetism is what happened, how to deal with? A: The generator (electric ball) for a long time, resulting in the loss of residual magneti...
    Read more
  • How to extend the service life of diesel generator set?

    How to extend the service life of diesel generator set?

    The use of generators is now more and more widespread in the market, broken will often change the machine, what way can save costs, buy cheap and afraid of unreliable quality, so as long as the life of the generator, the following to introduce how to increase the life of the diesel generator set ...
    Read more