News

  • The battery of a diesel generator can be started safely if there is enough power!

    The battery of a diesel generator can be started safely if there is enough power!

    Batteries are important for diesel generators, which can only be started effectively if there is sufficient power, which is necessary for each generator to be started successfully. Therefore, the guarantee of battery power is very important. Beidou believes that everyone should pay attention to t...
    Read more
  • Cummins Diesel Generator oil level abnormal analysis?

    Cummins Diesel Generator oil level abnormal analysis?

    When the Cummins diesel generator transformer is running, the normal flow must be maintained. The officer on duty must check the revised instructions immediately. When the oil level is too high (summer, etc.), it must be immediately supplemented when the oil level is too low (winter, etc.), and t...
    Read more
  • What causes the generator to fall short of its rated power?

    What causes the generator to fall short of its rated power?

    The reason why the generator can’t reach the rated power is that some regulars ask why the generator can’t reach the rated standard power. Our Beidou power engineers have summarized the following power shortage solutions. Low fuel pressure. Check for leaks or dents between the fuel su...
    Read more
  • How to prevent bubbling of fuel tank of diesel generator set?

    How to prevent bubbling of fuel tank of diesel generator set?

    How to prevent bubbling in the oil tank of the diesel generator set is because the high-pressure gas in the oil cylinder intrudes into the cooling waterway. The causes and methods of gas channeling are as follows. 1. The head nut is not fastened according to the specified torque. If the torque is...
    Read more
  • Correct use and maintenance of oil pump?

    Correct use and maintenance of oil pump?

    1. Before installing the oil pump of the diesel generator, it is necessary to confirm whether the model and specification are correct, remove the anti-rust oil, choose the thickness of the gasket appropriately, so that the piston is too thin or too thick, to prevent the piston from dying or worki...
    Read more
  • The 10 requirements and characteristics of diesel generator oil pump?

    The 10 requirements and characteristics of diesel generator oil pump?

    Diesel generator oil pump is an important part. Generally speaking, in order to ensure the use of the organs of the diesel generator set, great attention must be paid to the use and installation of the oil pump. 1. Before installing the oil pump, make sure that the model and specification are cor...
    Read more
  • Five failures of diesel generator set with low load exhaust pipe dripping oil?

    Five failures of diesel generator set with low load exhaust pipe dripping oil?

    Because the diesel engine has a number of eggplant pressure seals, such as between cylinder liner, piston and piston ring, and between turbocharger and turbocharger rotor shaft, it is generally only able to play a full role when the engine is about one-third of the load, and some leakage may occu...
    Read more
  • Is there usually electricity on the neutral line? Zero line? When is the electricity on?

    Is there usually electricity on the neutral line? Zero line? When is the electricity on?

    A lot of people talk about whether the neutral line has electricity or not in the general case. Anyway, there are two points of view. One has electricity, one is dead. As for whether there is biography, it actually confuses people’s concept of electrification, considering only their own vie...
    Read more
  • Diesel Engine Frequent Oil Leakage Fault Analysis?

    Diesel Engine Frequent Oil Leakage Fault Analysis?

    First, first, how to check the diesel generator: first check whether the type, quantity and quality of the oil meet the requirements. Second, diesel engine components of the combined surface is smooth, size processing is in line with the requirements. Dumping materials and die casting without san...
    Read more
  • Main fault precursor of diesel engine?

    Main fault precursor of diesel engine?

    Let’s look at the main failure precursors of diesel generators and the precursors of watt combustion. Diesel engine starts, speed drops sharply, load increases, the engine takes black smoke, oil pressure drops, crankcase issued dry friction sound “goo”, is the precursor of burni...
    Read more
  • Diesel generator Running in parallel Precautions?

    Diesel generator Running in parallel Precautions?

    To increase production efficiency, many companies have two generators. However, the parallel operation of generator sets is more than just mixing two generator sets. Diesel generator sets must also meet appropriate normal operating conditions. (1) The effective voltage value of the generator set ...
    Read more
  • Diesel generator valve abnormal and solution method?

    Diesel generator valve abnormal and solution method?

    The characteristics and causes of the noise in the operation of the generator are as follows: (1) The leakage noise of the outer valve of the high-load low-speed valve is obvious, and the noise increases with the increase of the load. The main causes are operating errors on the Dawn valve or exce...
    Read more