How to ensure that the power performance of the silent diesel generator set will not be reduced

The silent diesel generator set should be maintained after a period of use, and the maintenance of the silent diesel generator set should be strengthened before power supply. However, no matter what kind of maintenance, there should be a certain plan and steps, according to the requirements of disassembly and installation, reasonable use of tools, force should be appropriate. For example, when the diesel filter is assembled, if it is too tight, it will leak. In addition, during the assembly process, assembly should be carried out according to various standard torques. Only by carrying out irregular maintenance on the silent diesel generator set can we ensure that the power performance of the silent diesel generator set will not be reduced and the failure will be reduced.
The following describes the routine maintenance and the first, second and third technical maintenance of the silent diesel generator set.
I. Routine maintenance
The daily maintenance of silent diesel generator set is mainly to check the following contents: check the amount of oil in the tank, check the oil level and oil quality, check the three leakage (leakage, leakage, leakage), check the installation of silent diesel generator set accessories and instruments, check the injection pump transmission shaft joint plate, clean the appearance of silent diesel generator set.
Ii. Technical maintenance
In addition to routine maintenance items, the silent diesel generator set has worked for *00h in total. When * maintenance is required, the following inspection contents need to be added: Check the pressure of the generator carbon brush and compression spring; Check the welding and fastening of all parts in the control box; Check whether the value of the instrument is within the specified range, whether the manual and automatic are sensitive, whether the rheostat sliding line is disconnected, whether the switch is sensitive, whether the battery voltage meets the requirements; Check the tension of the triangle rubber belt; Clean the oil pan and various filters; Replace the oil; Grease the bearing of the feed water pump and the silent diesel generator set; Clean the cooling water radiator.
Third, secondary technical maintenance
In addition to the technical maintenance items, it is also necessary to check the injector and injection pump, adjust the valve clearance and oil supply front Angle, check the inlet and exhaust valve seal, check the pump leakage, check the cylinder head seal, check the radiator: tighten the components of the silent diesel generator set and clean the pipeline.
Four, three technical maintenance
In addition to secondary technical maintenance, the cylinder head assembly, piston connecting rod assembly, crankshaft assembly, transmission mechanism and valve phase, turbocharger, oil pump, fresh water pump, inlet/exhaust gasket, charging generator and starter motor should be checked.
The above four points are the technical maintenance methods of Kachen power generation equipment arrangement to ensure that the power of silent diesel generator sets will not be reduced for users’ reference.