Introductio ad modum usura 150kw generator set

Cum 150kw generator set deficit, a simplex iudicium fieri potest secundum aliquid on-site phaenomena. Ut sonus, celeritate, tempus, potestatem et sic in. Nos introduced quod analysis debet considerari cum reprehendo et troubleshooting generantis vitiis!

I. Iudicare defectum requirit analysis

Systematica analysis de defectum phaenomena, qui non potest confidunt in experientia ad instaurare unum component. Vos postulo scio quod systems et components mechanica apparatu sunt propinqua. Cum a ratio vel pars deficient, non necesse est involvere alia ratio components, causando variaing gradus damnum ad alias ratio components. Si vis solvere culpam oportet analyze causam culpae totam et miscere clavem cum clausis partes culpae et reparare in tempore absque relinquo occulti periculis.

II. Post defectum 150kw generantis set invenitur, Disassembly workload debet esse elevat

Cum apparatu deficit, ne caeculo disassemble generans. Ante Dismantling, secundum ipsam situ, in culpa location est praecipuum iudicatus, et altiore structuram principium et culpa location generantis set studuit. De ex scientia, targeted disassembly est peragatur ad redigendum in workload de disassembly, nisi tempus, et resumere productio quam primum.

III. Diligenter intueri, per compositum ex marialis et corporis odor

Cum Diesel generator set deficit, maxime ex illis sunt in productione site. In hoc non simplex situ, ibi est plerumque non respondentem testing apparatu. Sed in casu de urgente productio officia ad productionem site, culpa necessitates eliminated quam primum, ita sub normalis fortuna, non possumus videre, audi, tactus et odor aliam sensibilibus ad troubleshooting.

First observe the external characteristics of the generator during operation, such as whether the exhaust pipe smoke is normal, whether the oil color of the diesel generator set is abnormal, whether there are traces of diesel leakage in the oil system, whether there is oil leakage, water leakage, cooling system, lubrication system , Whether the indicators of the diesel generator set are abnormal, whether the nuts of the running parts are loose, whether the starting circuit wiring is Rectam, utrum internus circuitus potestate scrinium brevis, circuitus aut aperta, utrum vibratio de metris in Diesel generantis set normalis. Hoc apparatus est valde fortis per operationem.

Secundo, secundum audiendum, ut maxime invenimus, utrum sit alius sonitus in operatione generantis, et iudicare locum culpae secundum locum et naturam sonitus. During the operation of the equipment, pay attention to the impact of crankshafts, pistons, connecting rods, whether the noises of intake and exhaust valves, and transmission gears are abnormal, whether the explosion sound of diesel combustion in the combustion chamber is uniform, and abnormal noises may also occur when a single cylinder is turned off.

In terms of touch, it refers to the pulsation of the oil pipe and the vibration of the unit when the fault occurs, or whether the temperature of the oil pipe and oil shell of the 150KW generator set is the same as the oil temperature, whether the temperature of the generator shell is too high, and whether the water temperature is too high. Suus 'idem. De culpa generantis potest iudicari secundum temperatus mutatio, et locus et causa sui eventus potest etiam iudicari a praesentia vel absentia vibrationis.

Vos can quoque determinare utrum unitas est perna per suave. Si est arduam odor in potestate copia processus, significat quod generans est alius. Exempli gratia, si internus circuitus generantis, in components, in stator, in rotor et alios abnormes, si per pellentesque engine oleum urit, ibi erit aestuat phaenomenon. In ipsa productio processus, secundum rationem diversis vitiis et perficientur phaenomena, flexibile et mutabilis modo debet adhiberi ad diagnosi, et comprehensive analysis de culpa, et targeted modi ad eliminare causam.

8,10


Post tempus: Aug-10-2021