FD3 IV-polus tres-phase terrae generans potestatem | |||||||
50Hz (MD RPM) | 60Hz (MDCCC RPM) | ||||||
Genus H temperatus ortum (125k XL ℃) | Genus H temperatus ortum (125k XL ℃) | ||||||
Voltage (V) | Stella Topology | CCCLXXX | CD | CDXV | CDXL | CDLX | CDLXXX |
Stella parallelech topology | CXC | CC | CCVIII | CCXX | CCXXX | CCXL | |
Triangulum topology | CCXX | CCXXX | CCXL | CCLIV | CCLXVI | CCLXXVII | |
Trianguli parallel topology | CX | CXV | CXX | CXXVII | CXXXIII | CXXXIX | |
FD3A, IV | Rated capacitatem (KVA) | 100.0 | 100.0 | 100.0 | 117,5 | 117,5 | 125.0 |
Rated Power (KW) | 80.0 | 80.0 | 80.0 | 94.0 | 94.0 | 100.0 | |
Efficiente% | 89.9 | 90.3 | 90.6 | 90.5 | 90.8 | 91.0 | |
FD3B, IV | Rated capacitatem (KVA) | 114.0 | 114.0 | 114.0 | 137,5 | 137,5 | 146.3 |
Rated Power (KW) | 91.2 | 91.2 | 91.2 | 110.0 | 110.0 | 117,0 | |
Efficiente% | 90.3 | 90.6 | 91.0 | 90.8 | 91.2 | 91.3 | |
FD3C-IV | Rated capacitatem (KVA) | 125.0 | 125.0 | 125.0 | 150.0 | 150.0 | 160.0 |
Rated Power (KW) | 100.0 | 100.0 | 100.0 | 120.0 | 120.0 | 128.0 | |
Efficiente% | 90.3 | 90.8 | 91.0 | 90.4 | 90.7 | 91.3 | |
FD3DS, IV | Rated capacitatem (KVA) | 140.0 | 140.0 | 140.0 | 167.5 | 167.5 | 178.8 |
Rated Power (KW) | 112.0 | 112.0 | 112.0 | 134.0 | 134.0 | 143.0 | |
Efficiente% | 91.3 | 91.7 | 92.0 | 91.7 | 92.1 | 92.1 | |
FD3D-IV | Rated capacitatem (KVA) | 150.0 | 150.0 | 150.0 | 175,0 | 180.0 | 187,5 |
Rated Power (KW) | 120.0 | 120.0 | 120.0 | 140.0 | 144.0 | 150.0 | |
Efficiente% | 91.9 | 92.2 | 92.2 | 92.3 | 92.4 | 92.4 | |
FD3ES-IV | Rated capacitatem (KVA) | 160.0 | 160.0 | 160.0 | 190.0 | 190.0 | 206.3 |
Rated Power (KW) | 128.0 | 128.0 | 128.0 | 152.0 | 152.0 | 165.0 | |
Efficiente% | 92.0 | 92.3 | 92.5 | 92.5 | 92.7 | 92.7 | |
FD3em-IV | Rated capacitatem (KVA) | 182.0 | 182.0 | 182.0 | 218,5 | 218,5 | 231.4 |
Rated Power (KW) | 145,6 | 145,6 | 145,6 | 174,8 | 174,8 | 185,1 | |
Efficiente% | 92.0 | 92.4 | 92.6 | 92.4 | 92.7 | 92.7 | |
FD3E, IV | Rated capacitatem (KVA) | 188.0 | 188.0 | 188.0 | 235,0 | 235,0 | 240.0 |
Rated Power (KW) | 150.4 | 150.4 | 150.4 | 188.0 | 188.0 | 192.0 | |
Efficiente% | 92.2 | 92.2 | 92.3 | 92.4 | 92.4 | 92.7 | |
FD3F-IV | Rated capacitatem (KVA) | 200.0 | 200.0 | 200.0 | 245,0 | 245,0 | 255,0 |
Rated Power (KW) | 160.0 | 160.0 | 160.0 | 196.0 | 196.0 | 204.0 | |
Efficiente% | 92.2 | 92.2 | 92.3 | 92.6 | 92.6 | 92.8 | |
FD3G, IV | Rated capacitatem (KVA) | 230.0 | 230.0 | 230.0 | 282,5 | 282,5 | 300.0 |
Rated Power (KW) | 184.0 | 184.0 | 184.0 | 226,0 | 226,0 | 240.0 | |
Efficiente% | 92.2 | 92.5 | 92.7 | 92.7 | 92.8 | 92.8 | |
FD3H-IV | Rated capacitatem (KVA) | 250.0 | 250.0 | 250.0 | 300.0 | 312.5 | 312.5 |
Rated Power (KW) | 200.0 | 200.0 | 200.0 | 240.0 | 250.0 | 250.0 | |
Efficiente% | 92.5 | 92.7 | 92.8 | 92.7 | 92.8 | 92,9 |