FD1 IV-polus tres-phase terrae generans potestatem | |||||||
50Hz (MD RPM) | 60Hz (MDCCC RPM) | ||||||
Genus H temperatus ortum (125k XL ℃) | Genus H temperatus ortum (125k XL ℃) | ||||||
Voltage (V) | Stella Topology | CCCLXXX | CD | CDXV | CDXL | CDLX | CDLXXX |
Stella parallelech topology | CXC | CC | CCVIII | CCXX | CCXXX | CCXL | |
Triangulum topology | CCXX | CCXXX | CCXL | CCLIV | CCLXVI | CCLXXVII | |
Trianguli parallel topology | CX | CXV | CXX | CXXVII | CXXXIII | CXXXIX | |
FD1A, IV | Rated capacitatem (KVA) | 8,1 | 8,1 | 8,1 | 10,2 | 10,2 | 10,2 |
Rated Power (KW) | 6,5 | 6,5 | 6,5 | 8,0 | 8,0 | 8,0 | |
Efficientiam% | 75.6 | 76.2 | 76.6 | 76.3 | 76.9 | 77.4 | |
FD1B, IV | Rated capacitatem (KVA) | 11.0 | 11.0 | 11.0 | 13,8 | 13,8 | 13,8 |
Rated Power (KW) | 8,8 | 8,8 | 8,8 | 11.0 | 11.0 | 11.0 | |
Efficientiam% | 78.8 | 79.4 | 79.8 | 79.4 | 80.0 | 80.5 | |
FD1c-IV | Rated capacitatem (KVA) | 13,5 | 13,5 | 13,5 | 16,9 | 16,9 | 16,9 |
Rated Power (KW) | 10,8 | 10,8 | 10,8 | 13,5 | 13,5 | 13,5 | |
Efficientiam% | 80.0 | 80.7 | 81.0 | 80.7 | 81.3 | 81.7 | |
FD1D-IV | Rated capacitatem (KVA) | 16.0 | 16.0 | 16.0 | 20.0 | 20.0 | 20.0 |
Rated Power (KW) | 12,8 | 12,8 | 12,8 | 16.0 | 16.0 | 16.0 | |
Efficientiam% | 81.0 | 81.6 | 81.9 | 81.7 | 82.2 | 82.7 | |
FD1es-IV | Rated capacitatem (KVA) | 18.8 | 18.8 | 18.8 | 23.0 | 23.0 | 23.0 |
Rated Power (KW) | 15.0 | 15.0 | 15.0 | 18,5 | 18,5 | 18,5 | |
Efficientiam% | 81.7 | 82.4 | 83.1 | 83.1 | 83.9 | 84.5 | |
FD1E, IV | Rated capacitatem (KVA) | 22.5 | 22.5 | 22.5 | 28.8 | 28.8 | 30.0 |
Rated Power (KW) | 18.0 | 18.0 | 18.0 | 23.0 | 23.0 | 24.0 | |
Efficientiam% | 84.3 | 84.9 | 85.3 | 84.3 | 84.9 | 85.2 | |
FD1F, IV | Rated capacitatem (KVA) | 27,5 | 27,5 | 27,5 | 34.4 | 34.4 | 35.0 |
Rated Power (KW) | 22.0 | 22.0 | 22.0 | 27,5 | 27,5 | 28.0 | |
Efficientiam% | 85.7 | 86.2 | 86.5 | 85.9 | 86.4 | 86.7 | |
FD1G, IV | Rated capacitatem (KVA) | 31.3 | 31.3 | 31.3 | 37,5 | 37,5 | 37,5 |
Rated Power (KW) | 25.0 | 25.0 | 25.0 | 30.0 | 30.0 | 30.0 | |
Efficientiam% | 86,6 | 87.0 | 87.2 | 87.0 | 87.3 | 87.6 | |
FD1GL-IV | Rated capacitatem (KVA) | 35.0 | 35.0 | 35.0 | 42.0 | 42.0 | 42.0 |
Rated Power (KW) | 28.0 | 28.0 | 28.0 | 33.6 | 33.6 | 33.6 | |
Efficientiam% | 86.3 | 86.4 | 86.4 | 87.6 | 87.8 | 87.9 | |
FD1J, IV | Rated capacitatem (KVA) | 37,5 | 37,5 | 37,5 | 45.0 | 45.0 | 45.0 |
Rated Power (KW) | 30.0 | 30.0 | 30.0 | 36.0 | 36.0 | 36.0 | |
Efficientiam% | 86.7 | 87.2 | 87.4 | 87.2 | 87.5 | 87.8 | |
FD1K, IV | Rated capacitatem (KVA) | 40.0 | 40.0 | 40.0 | 50.0 | 50.0 | 50.0 |
Rated Power (KW) | 32.0 | 32.0 | 32.0 | 40.0 | 40.0 | 40.0 | |
Efficientiam% | 87.3 | 87.6 | 87.9 | 87.8 | 88.2 | 88.6 |
FD1 II-polus tres-phase terrae generans potestatem | |||||||
| 50Hz (3000rpm) | 60Hz (3600RPM) | |||||
| Genus H temperatus ortum (125k XL ℃) | Genus H temperatus ortum (125k XL ℃) | |||||
Voltage (V) | Stella Topology | CCCLXXX | CD | CDXV | CDXL | CDLX | CDLXXX |
Stella parallelech topology | CXC | CC | CCVIII | CCXX | CCXXX | CCXL | |
Triangulum topology | CCXX | CCXXX | CCXL | CCLIV | CCLXVI | CCLXXVII | |
Trianguli parallel topology | CX | CXV | CXX | CXXVII | CXXXIII | CXXXIX | |
FD1A-II | Rated capacitatem (KVA) | 12,5 | 12,5 | 12,5 | 15,6 | 15,6 | 15,6 |
Rated Power (KW) | 10.0 | 10.0 | 10.0 | 12,5 | 12,5 | 12,5 | |
Efficiente% | 73.7 | 74.2 | 74.5 | 72.8 | 73.2 | 73.5 | |
FD1B-II | Rated capacitatem (KVA) | 15.0 | 15.0 | 15.0 | 18.8 | 18.8 | 18.8 |
Rated Power (KW) | 12.0 | 12.0 | 12.0 | 15.0 | 15.0 | 15.0 | |
Efficiente% | 76.2 | 77.0 | 77.5 | 75.4 | 76.2 | 76.7 | |
FD1c-II | Rated capacitatem (KVA) | 17,5 | 17,5 | 17,5 | 21,9 | 21,9 | 21,9 |
Rated Power (KW) | 14.0 | 14.0 | 14.0 | 17,5 | 17,5 | 17,5 | |
Efficiente% | 78.4 | 79.1 | 79.5 | 77.7 | 78.3 | 78.9 | |
FD1ds-II | Rated capacitatem (KVA) | 20.0 | 20.0 | 20.0 | 23.0 | 23.0 | 23.0 |
Rated Power (KW) | 16.0 | 16.0 | 16.0 | 18.4 | 18.4 | 18.4 | |
Efficiente% | 80.0 | 80.2 | 80.5 | 79.7 | 79.9 | 80,1 | |
FD1D-II | Rated capacitatem (KVA) | 25.0 | 25.0 | 25.0 | 31.3 | 31.3 | 31.3 |
Rated Power (KW) | 20.0 | 20.0 | 20.0 | 25.0 | 25.0 | 25.0 | |
Efficiente% | 82.0 | 82.6 | 83.0 | 81.5 | 82.1 | 82.5 | |
FD1E-II | Rated capacitatem (KVA) | 30.0 | 30.0 | 30.0 | 35.0 | 35.0 | 35.0 |
Rated Power (KW) | 24.0 | 24.0 | 24.0 | 28.0 | 28.0 | 28.0 | |
Efficiente% | 82.6 | 83.1 | 83.5 | 81.9 | 82.4 | 82.8 | |
FD1F-II | Rated capacitatem (KVA) | 35.0 | 35.0 | 35.0 | 40.0 | 40.0 | 40.0 |
Rated Power (KW) | 28.0 | 28.0 | 28.0 | 32.0 | 32.0 | 32.0 | |
Efficiente% | 84.1 | 84.5 | 84.8 | 83.4 | 83.9 | 84.2 | |
FD1G-II | Rated capacitatem (KVA) | 37,5 | 37,5 | 37,5 | 46.9 | 46.9 | 46.9 |
Rated Power (KW) | 30.0 | 30.0 | 30.0 | 37,5 | 37,5 | 37,5 | |
Efficiente% | 84.8 | 85.2 | 85.5 | 84.3 | 84.7 | 85.0 |