5KVA-500KVA Marathon Generator MagnaPlus Series Alternator

Short Description:

Advantages:

 1. Outstanding electric characteristic

Steady voltage regulation is less than 0.25%.

Transient voltage regulation is less than +20%, -15%(60%IN,P.F≤0.4lag).

Voltage adjusting range is over than 10% of Un.

Total voltage waveform distortion is less than 5%(L-L).

The steady short circuit is ≥300%In, and maintain time ≥10s.

It has wide stability range as using in non-linear load condition.

Good motor starting capacity.

Good paralleling performance.

2. Unique structure

Full guarded screen and louvers for operator safety. Unique ventilation and cooling may be efficient heat transfer and good windings cooling.

Brushless generator with PMG exciting system. It can provide 300% in safety short circuit current, and maintain time 10s. It has not the trouble of lost residue magnetism.

Salient unirotor construction. Rotor core closly coupled with die cast damping winding. The field windings are layer wound with thermo-setting epoxy for high mechanical and electrical integrity.

DVR2000E+ digital voltage regulator is encapsulated for reliable performance in varying environment such as protecting moisture and anti-vibration.

It’s voltage regulation has high accuracy about 0.25%. It include adjustable voltage, stability and volt/herz under speed protection, three phase RMS sensing, papalleling, over excition, over voltage protection and so on as standard.

End mounted conduit-box located at the rear of frame, It provides ample space to fit attachments and elements, and 4 bars may be connected easily to load.

H class insulation system.

Bearing is double shielded and pre-lubricated for long life.

Sae standard adaption.

Exciter, PMG and rectifier assembly loacted outboard of bearing for easy of inspection and maintenance.


Product Detail

Product Tags

Alternator Model

Rating Capacity

Voltage

V

Frequency

HZ

Rated RPM

 

Kw

Kva

GM-8.6-4

8.6

10.75

400

50

1500

GM-12-4

12

15

400

50

1500

GM-16-4

16

20

400

50

1500

GM-20-4

20

25

400

50

1500

GM-24-4

24

30

400

50

1500

GM-30-4

30

37.5

400

50

1500

GM-32-4

32

40

400

50

1500

Alternator Model

Rating Capacity

Voltage

V

Frequency

HZ

Rated RPM

Kw

Kva

MP-40-4

40

50

400

50

1500

MP-48-4

48

60

400

50

1500

MP-50-4

50

62.5

400

50

1500

MP-58-4

58

72.5

400

50

1500

MP-64-4

64

80

400

50

1500

MP-70-4

70

87.5

400

50

1500

MP-75-4

75

93.5

400

50

1500

MP-80-4

80

100

400

50

1500

MP-90-4

90

112.5

400

50

1500

MP-104-4

104

130

400

50

1500

MP-120-4

120

150

400

50

1500

 

Alternator Model

Rating Capacity

Voltage

V

Frequency

HZ

转速

RPM

Kw

Kva

MP-120-4A

120

150

400

50

1500

MP-140-4A

140

175

400

50

1500

MP-160-4A

160

200

400

50

1500

MP-180-4A

180

225

400

50

1500

MP-200-4A

200

250

400

50

1500

MP-217-4A

217

271.25

400

50

1500

MP-220-4A

220

275

400

50

1500

MP-240-4A

240

300

400

50

1500

MP-250-4A

250

312.5

400

50

1500

MP-260-4A

260

325

400

50

1500

MP-280-4A

280

350

400

50

1500

MP-300-4A

300

375

400

50

1500

MP-320-4A

320

400

400

50

1500


  • Previous:
  • Next: